| Home | E-Submission | Sitemap | Contact Us |  
top_img
J Radiat Prot > Volume 15(2); 1990 > Article
Journal of Radiation Protection 1990;15(2):75-0.
Karlsruhe 원자력연구소 주변의 환경방사능 측정자료로부터 실효선량당량계산
이창우;이정호;;
A Calculation of Effective Dose Equivalent from Data of Environmental Monitoring around the Karlsruhe Nuclear Research Center
Lee, Chang-Woo;Lee, Jeong-Ho;Wicke, A.;
ABSTRACT
The dose calculations were carried out using environmental montoring data around Karlsruhe Nuclear Research Center(KfK). Ingestion of plant foods was the most important pathway, and the K-40 and Pb-210 natural radioisotopes in food were the most effective radiation source to man. The dose received from artificial nuclides were mostly emitted by gamma irradiation of Cs-134 and Cs-137 deposited on the ground. The effective dose equivalent in the KfK environment was far less than the dose equivalent limit recommended by ICRP.
TOOLS
PDF Links  PDF Links
Full text via DOI  Full text via DOI
Download Citation  Download Citation
Share:      
METRICS
988
View
8
Download
A Theoretical Calculation of Photon Dose Equivalent Conversion Factor For Extremity Dosimeter  1996 ;21(1)
Editorial Office
#319, Hanyang Institute of Technology Bldg., 222 Wangsimni-ro, Seongdong-gu,Seoul, Republic of Korea
Tel: +82-2-2297-9775   Fax: +82-2-2297-9776
Email: jrpr.editorial@gmail.com
About |  Browse Articles |  Current Issue |  For Authors and Reviewers
Copyright © by Korean Association for Radiation Protection. Developed in M2PI