Matsumoto, Shinsho, Miura, Murakami, Ito, and Nishimura: Integrated Evaluation of an Augmented Reality-Based Radiation Protection Education Program for Nursing Students
Abstract
Background
Radiation plays a vital role in medical diagnosis and treatment. However, insufficient radiation protection education poses serious risks to patients and healthcare professionals. Nursing students often have limited formal training, and traditional lecture-based methods foster passive learning, which may not promote deep understanding. Augmented reality (AR) technology offers a novel approach by overlaying digital models onto real-world images, enabling students to intuitively visualize abstract concepts such as time, distance, and shielding. This study was conducted to evaluate an AR-based radiation protection application integrated with conventional lectures to enhance the knowledge of nursing students and calibrate their perceptions of radiation safety.
Materials and Methods
A cross-sectional, pre–post-intervention study was conducted at Tokyo Metropolitan University among 80 second-year nursing students (95% female) without prior radiation safety training. The intervention comprised two phases: a standardized 90-minute lecture covering the nature and biological effects of ionizing radiation and the principles of time, distance, and shielding; and a hands-on AR session using an Android-based application that overlays a three-dimensional model of scattered radiation dose onto a live camera view, demonstrating exposure effects. Radiation knowledge was assessed using a 50-item questionnaire, and risk perception was measured using a 30-item, seven-point Likert scale. Data in this study were analyzed using nonparametric tests and compared with reference data.
Results and Discussion
Post-intervention knowledge scores were significantly higher than pre-intervention and reference scores (p<0.05). Additionally, risk perception ratings for ‘nuclear power’ and ‘X-ray’ decreased by one rank, suggesting a more balanced and realistic evaluation of risks.
Conclusion
Integrating AR with traditional lectures significantly improves radiation protection knowledge and risk assessment among nursing students, supporting the promising role of AR in healthcare education. Future research should include longitudinal follow-up and explore AR features, such as dose simulation.
Keywords: Augmented Reality, Radiation Protection, Nursing Education, Risk Perception, Nonparametric Statistics
Introduction
Although radiation is extensively used in medical diagnosis and treatment, inadequate radiation protection measures can expose patients and healthcare workers to significant health risks. However, opportunities for nursing students to receive comprehensive education on radiation safety remain limited, raising concerns regarding effective risk management in clinical settings [ 1]. Traditionally, many nursing programs have relied on lecture-based, one-way information delivery, resulting in a passive learning environment that hinders the deep understanding and development of practical clinical skills [ 2].
In addition, Yoshida et al. [ 3] assessed the level of understanding among Japanese nursing students who had received standard radiation education, using terminology from radiation-related teaching materials intended for junior high school students. Their findings revealed consistently low recognition and understanding of these terms across all academic years (first through fourth). Using a four-point scale (3=fully understood, 2=somewhat known, 1=heard of, 0=not known), they found that approximately 60% of the items had an average score below 1.0. Moreover, no significant difference in scores was observed between academic years, suggesting that conventional lecture-based instruction failed to effectively improve students’ understanding of radiation-related concepts. These findings underscore the need for instructional approaches that go beyond conventional lectures.
As a potential solution to these challenges, recent technological advances—particularly augmented reality (AR)—enable the overlay of digital models onto real-world images to visually depict previously imperceptible radiation distributions and effects, thereby fostering intuitive understanding among students [ 4– 6]. Prior studies have reported educational benefits of AR, including improved understanding of radiation protection among radiological technology students [ 4], enhanced independent thinking and creativity [ 5], and increased comprehension with experimental support [ 6]. Yet, within nursing education, the quantitative impact of AR on knowledge and risk perception remains untested.
Therefore, the aim of the present study was to develop and evaluate a radiation protection education program that incorporates AR technology and to assess its effectiveness in enhancing the knowledge of nursing students and calibrating their risk perception, compared with conventional lecture-based methods.
Materials and Methods
1. Study Design and Population
A cross-sectional, pre–post-intervention study was conducted at Tokyo Metropolitan University (TMU). In January 2025, a full census of all second-year nursing students enrolled in the School of Nursing was carried out. A total of 80 students (four males and 76 females) participated, none of whom had received prior formal education in radiation protection. There were no refusals or exclusions, making the sample representative of the entire second-year nursing student population at TMU. In addition, reference data from a previously published study involving first- to fourth-year nursing students from another institution were used for comparative analysis. This study was approved by the Institutional Review Board of TMU (approval number: 22067).
Limitations inherent to the design include the single-site sample at TMU (predominantly female) and the integrated delivery of the lecture and AR components, which may limit generalizability and preclude attribution of effects to individual components.
2. Educational Intervention
The educational intervention was designed in two sequential phases: lecture- and AR-based practices.
1) Lecture component
Participants attended a 90-minute didactic lecture covering the following topics:
• An overview of diagnostic imaging modalities (X-ray, angiography, computed tomography, magnetic resonance imaging, and nuclear medicine), along with precautions when accompanying patients
• A basic introduction to radiotherapy equipment and examples of acute side effects during treatment
• The health effects of radiation exposure, including tissue reactions (with threshold doses) and stochastic effects (e.g., cancer risk models such as the linear no-threshold)
• Occupational dose limits for radiation workers
• The three fundamental principles of radiation protection: time, distance, and shielding
To ensure consistency within our site, the entire cohort attended a single session delivered by the same instructor using an identical slide deck and scripted sequence.
2) AR-based practical session
Following the lecture, students participated in a 90-minute hands-on AR session using a custom-developed Android-based AR application [ 7]. This session was designed to reinforce key principles of radiation protection—specifically distance, shielding, and time—by enabling students to visually observe the distribution of scattered radiation dose in a simulated portable X-ray environment.
Technical specifications of the AR application:
• The application featured three-dimensional (3D) computer-generated models of a patient, a radiological technologist, a portable X-ray unit, and color-coded boxes that changed based on radiation dose levels.
• In the default scene, the patient model is seated on the bed at the coordinate origin, the technologist stands at the foot of the bed facing the patient, and the portable X-ray unit is placed at the foot side to simulate a seated chest radiograph.
• Color-coded boxes were arranged at 10 cm intervals around the bed, and their colors reflected ambient dose equivalents calculated through Monte Carlo simulations of scattered radiation.
• A tablet camera was used to overlay these 3D models onto the real-world environment, using a QR code placed on the bed as the spatial reference point.
• An interactive panel, which students could position freely, displayed the observer’s location, distance from the patient, and estimated ambient dose equivalent.
Instructional components:
• Distance: Students measured dose values at 50, 100, 150, and 200 cm from the patient model. They recorded data, created graphs, and discussed the inverse relationship between distance and radiation exposure.
• Shielding: Students compared dose values in scenarios with and without shielding (e.g., with a technologist or equipment placed between the patient and observer), calculated dose reduction, and discussed the effectiveness of shielding.
• Time (conceptual understanding): Although the application did not allow direct manipulation of time, students conceptually explored its effect by calculating how many exposures would be required to reach a reference dose (100 mSv) under various conditions.
This AR-based session provided students with an interactive learning experience, deepening their understanding of spatial positioning and shielding effects on radiation exposure and reinforcing theoretical concepts from the preceding lecture.
3. Evaluation Instruments
To evaluate the impact of the intervention, two separate questionnaires were administered: one assessing knowledge and the other assessing risk perception. These were developed and implemented independently, as they targeted distinct outcome constructs. Fig. 1 presents an overview of the study design.
1) Knowledge assessment
A 50-item questionnaire comprising selected phrases from supplementary educational materials on radiation [ 8] was administered before and after the intervention. Nursing students rated their understanding of each phrase on a four-point scale (3=thorough understanding, 2=some knowledge, 1= have heard of it, and 0=no knowledge). Average understanding scores were compared between the pre- and post-intervention assessments and results reported in previous studies.
To assess the impact of the combined lecture and AR-based educational intervention, we used the same knowledge questionnaire as in a previous study [ 6]. The questionnaire covers key concepts in radiation protection, including types of radiation (e.g., X-rays and gamma rays), radiation units (sievert [Sv] and Gy), radiation risks, radiation characteristics (e.g., penetration and biological effects), and the three principles of protection (time, distance, and shielding). This instrument was designed to assess fundamental radiation protection terminology and was used to ensure content consistency and comparability across studies.
2) Risk perception assessment
To assess participants’ risk perception, we employed a ranking-based method grounded in the psychometric paradigm proposed by Slovic et al. [ 9]. Participants ranked 30 different activities or technologies, including radiation-related sources (e.g., nuclear power and X-rays), according to perceived risk (1=highest risk and 30=lowest risk).
The item list and pre- and post-intervention rankings are shown in Table 1, alongside comparative data from first- to fourth-year nursing students reported by Yoshida et al. [ 3]. This format and item set were used to maintain consistency with previous research protocols, enabling meaningful comparisons. Although not a standardized instrument, its theoretical foundation and prior use in nursing education support its suitability for this study.
3) Comparative analysis
To evaluate the effectiveness of the AR-based educational intervention, knowledge and risk perception scores from the TMU cohort (pre- and post-intervention) were compared with reference data from a previous study [ 6] involving nursing students at another university who had received conventional lecture-based radiation education. The comparison group had participated in mandatory radiation lectures during their first and fourth years, with access to an optional 15-hour elective course. According to the original study authors, these students were considered to have above-average radiation-related knowledge for nursing students.
The same questionnaires were used in both studies to ensure consistency in measurement.
4) Statistical analysis
For knowledge scores, comparisons among three groups—TMU pre-intervention, TMU post-intervention, and the reference group—were conducted using the nonparametric Mann–Whitney U-test owing to non-normal data distributions. For risk perception scores, paired Student’s t-tests were used within the TMU group to assess pre- and post-intervention changes.
All statistical analyses were performed using Python version 3.12.7 (Python Software Foundation), with the significance level set at p<0.05.
Results
1. Knowledge Assessment
Fig. 2 presents the average knowledge scores. Among TMU second-year students, post-intervention scores were significantly higher ( p<0.05) than pre-intervention and reference (first- to fourth-year nursing students in a previous study) scores. In contrast, no statistically significant difference was found between the pre-intervention and reference scores, indicating that the baseline knowledge levels were comparable.
At the item level (50 items), paired tests within the TMU cohort with Benjamini–Hochberg correction indicated significant gains for 45/50 items (p<0.05). The clearest improvements occurred for items aligned with the intervention—Sv, 100 mSv, ambient dose equivalent rate, absorbed dose (Gy), principles of time–distance–shielding, and occupational dose limits—whereas items not covered (e.g., Fukushima Daiichi accident, the atomic bombings of Hiroshima and Nagasaki, evacuation order zones) showed no significant change.
Consistent with AR’s support for spatial understanding, items requiring spatial reasoning—such as the time–distance–shielding principles and dose measures—showed larger pre–post gains, whereas historical/social items changed little. Correspondingly, the largest item-level improvements occurred in content explicitly taught and practiced with the lecture plus AR (dose units [Sv and Gy], 100 mSv, time–distance–shielding, and occupational limits).
2. Risk Perception
After the AR-based intervention, TMU second-year students exhibited a one-rank reduction in perceived risk for specific radiation sources—nuclear power and X-ray—when measured on a seven-point scale. This shift was observed when compared with pre-intervention ratings and reference data, suggesting that the intervention led to a more balanced and realistic appraisal of radiation risks ( Table 1).
Fig. 3 illustrates the average score of each risk perception item. The items ‘nuclear power’ and ‘X-ray’ exhibited significant decreases in average scores from pre- to post-intervention. The risk perception ranking for nuclear power was ‘1’ before the intervention and also among first- through fourth-year students in the reference group; however, it shifted to ‘2’ after the intervention in the TMU cohort. For X-rays, the TMU cohort ranked the perceived risk as ‘6’ before the intervention and ‘7’ after. In contrast, the rankings in the reference group were ‘5,’ ‘4,’ ‘8,’ and ‘9’ for first- through fourth-year students, respectively, indicating a trend toward lower perceived risk (i.e., higher ranking) in the upper academic years.
Discussion
The findings suggest that integrating AR-based practical sessions with conventional lectures can enhance radiation protection education for nursing students. Although nursing curricula at other universities include general radiation lectures within a 4-year program, second-year students at TMU —who had not previously received formal radiation safety training—achieved significantly higher knowledge scores after the AR intervention than before and also outperformed nursing students from other universities. This improvement may be attributed to the interactive features of AR, which likely supported a better understanding of dose-related concepts. Previous research has indicated that this interactive and immersive approach promotes deeper understanding and enhances retention benefits that are not achieved by conventional lectures alone [ 4, 5]. The intervention provided a conceptual foundation through a brief lecture and then used the AR application (visualization and manipulation) to make invisible dose fields visible and to allow operations within a realistic spatial layout, thereby strengthening spatial reasoning. Accordingly, effects emerged selectively for concepts that require spatial understanding, with limited direct impact on historical/social knowledge. Consistent with the item-level results in Results section (1. Knowledge Assessment), these item-level patterns suggest targeted learning on content explicitly addressed by the lecture and AR session, with minimal spillover to historical/societal topics not covered. For first- and second-year students without clinical placements, AR likely bridged theory and practice by mapping abstract lecture content onto realistic spatial configurations. This helped students anchor dose-related concepts (e.g., time–distance–shielding and dose units) to observable cues in a simulated clinical layout. Furthermore, we observed that the AR intervention reduced risk ratings for ‘nuclear power’ and ‘X-ray’ by one rank on a seven-point scale. Since prior research has shown that individuals without sufficient radiation safety education tend to overestimate such risks owing to emotional and catastrophic associations [ 9], this reduction reflects a shift toward a more realistic and balanced perception of radiation hazards. The lecture provided quantitative, comparative information on cancer risk, whereas the AR session contextualized radiation exposure in clinical settings. Together, these components may have helped students develop a more accurate understanding of the actual magnitude of radiation risks, potentially countering exaggerated fears stemming from events like the Fukushima Daiichi accident, which directly associate nuclear power and radiation with cancer.
Regarding X-rays, the TMU cohort’s post-intervention risk perception ranking was ‘7,’ whereas the rankings among third- and fourth-year students in the reference group were ‘8’ and ‘9,’ respectively, indicating that upper-year students in the reference group perceived X-rays as less risky (i.e., ranked them higher). This difference may be attributed to clinical training, which typically begins in the third year in Japanese nursing programs. Increased exposure to real-world imaging procedures, such as observing X-ray examinations during clinical placements, may help students develop a more concrete understanding of radiation use. This experiential knowledge could reduce psychological anxiety and lead to a lower perceived risk.
This bridging effect is particularly relevant for early-year students who have not yet had clinical exposure. Overall, these results indicate that AR technology bridges the gap between theoretical knowledge and practical applications, leading to improved learning outcomes and more objective risk assessments.
Taken together, these findings suggest a transferable instructional framework for teaching spatial radiation protection concepts: (1) confirm prerequisite knowledge through a brief lecture; (2) engage learners in AR-based manipulation with immediate quantitative feedback; (3) consolidate learning by graphing measured values and providing concise explanations; and (4) translate insights into practical clinical decision rules (e.g., ‘maintain ≥2 m when feasible’).
Despite these promising outcomes, the limitations of this study warrant consideration. First, our sample was drawn from a single institution, and the participants were predominantly female, which may limit the generalizability of our findings. Second, as the intervention combined a standardized lecture with an AR-based practical session, we could not isolate the individual effects of each component. Consequently, it remains unclear whether the improvements in radiation knowledge and risk perception are primarily attributable to the interactive AR experience, conventional lectures, or their combined effect. Future studies employing designs that evaluate these components separately are necessary to elucidate their distinct contributions.
Conclusion
In summary, integrating a didactic lecture with an AR-based practical session appears to strengthen understanding of radiation and to recalibrate perceived risks for radiation-related items. These findings support the promising role of AR in healthcare education. Future research should disentangle the respective effects of the didactic lecture and the AR practical session.
References
1. Ohno K, Kaori T. Effective education in radiation safety for nurses. Radiat Prot Dosimetry. 2011;147(1–2):343-345.
2. Bligh DA. What’s the use of lectures?. Jossey-Bass; 2000.
3. Yoshida M, Iwamoto S, Okahisa R, Kishida S, Sakama M, Honda E. Knowledge and risk perception of radiation for Japanese nursing students after the Fukushima Nuclear Power Plant disaster. Nurse Educ Today. 2020;94:104552.
4. Fujibuchi T. Radiation protection education using virtual reality for the visualisation of scattered distributions during radiological examinations. J Radiol Prot. 2021;41(4):S317.
5. Bower M, Howe C, McCredie N, Robinson A, Grover D. Augmented reality in education: cases, places and potentials. Educ Media Int. 2017;54(1):1-15.
6. Ibanez MB, Delgado-Kloos C. Augmented reality for STEM learning: a systematic review. Comput Educ. 2018;123:109-123.
7. Matsumoto S, Shinsho K, Eisuke K, Tanaka Y, Ito Y, Nishimura Y. Development of augmented reality-based radiation protection application for healthcare professionals. J Radiat Prot Res. 2024;49(3):114-120.
8. Ministry of Education, Culture, Sports, Science and Technology. Radiation safety supplementary materials for elementary, middle, and high school education. Ministry of Education, Culture, Sports, Science and Technology; 2014. (Japanese).
9. Slovic P, Fischhoff B, Lichtenstein S. Perceived risk: psychological factors and social implications. Proc R Soc A. 1981;376(1764):17-34.
Fig. 1
Study design flowchart. The diagram outlines participant recruitment, pre- and post-intervention assessments, an educational intervention combining a lecture and an augmented reality (AR) activity, and the statistical analyses (Mann–Whitney U test and paired t-test; p<0.05).
Fig. 2
Average knowledge scores. a)Data from Yoshida et al. [ 3]. *Statistical significance ( p<0.05).
Fig. 3
Average risk perception score for each item. The plots display mean risk perception scores, with error bars representing the standard deviation of responses. *Statistical significance (p<0.05).
Table 1
|
Pre-intervention |
Post-intervention |
First-year nursing students |
Second-year nursing students |
Third-year nursing students |
Fourth-year nursing students |
|
Nuclear power |
1 |
2 |
1 |
1 |
1 |
1 |
|
Handguns |
2 |
1 |
2 |
2 |
2 |
2 |
|
Fire fighting |
3 |
3 |
6 |
5 |
5 |
5 |
|
Smoking |
4 |
4 |
3 |
3 |
3 |
3 |
|
Surgery |
5 |
5 |
10 |
7 |
7 |
7 |
|
X-rays |
6 |
7 |
5 |
4 |
8 |
9 |
|
Private aviation |
7 |
10 |
23 |
18 |
11 |
17 |
|
Motorcycles |
8 |
6 |
4 |
9 |
4 |
4 |
|
Large construction |
9 |
8 |
7 |
6 |
6 |
6 |
|
Hunting |
10 |
12 |
14 |
11 |
14 |
13 |
|
Motor vehicles |
11 |
9 |
15 |
12 |
9 |
8 |
|
Alcoholic beverage |
12 |
11 |
9 |
14 |
13 |
13 |
|
Mountain climbing |
14 |
17 |
18 |
15 |
16 |
14 |
|
Power mowers |
15 |
13 |
20 |
16 |
18 |
19 |
|
Pesticides |
16 |
18 |
11 |
8 |
10 |
10 |
|
Skiing |
17 |
25 |
28 |
26 |
23 |
22 |
|
Football |
18 |
21 |
12 |
22 |
15 |
15 |
|
Electric power |
20 |
23 |
25 |
23 |
20 |
24 |
|
Prescription antibiotics |
21 |
16 |
8 |
13 |
21 |
23 |
|
Contraceptives |
22 |
20 |
19 |
19 |
25 |
28 |
|
Food preservatives |
23 |
19 |
16 |
20 |
26 |
21 |
|
Spray cans |
24 |
22 |
21 |
21 |
22 |
27 |
|
Vaccinations |
25 |
24 |
24 |
25 |
26 |
25 |
|
Railroads |
26 |
26 |
27 |
27 |
19 |
20 |
|
Bicycles |
27 |
27 |
26 |
28 |
28 |
26 |
|
Food coloring |
28 |
29 |
13 |
24 |
27 |
18 |
|
Commercial aviation |
29 |
14 |
22 |
17 |
17 |
16 |
|
Home appliances |
29 |
28 |
29 |
30 |
30 |
29 |
|
Swimming |
30 |
30 |
30 |
29 |
29 |
30 |
|
|