| Home | E-Submission | Sitemap | Contact Us |  
top_img
J Radiat Prot > Volume 14(2); 1989 > Article
Journal of Radiation Protection 1989;14(2):18-0.
공기중의 라돈 농도 측정을 위한 CR-39의 교정
박영웅;장시영;하정우;노성기;
Calibration of CR-39 for Measurement of Radon in Air
Park, Y.W.;Chang, S.Y.;Ha, C.W.;Ro, S.G.;
ABSTRACT
In order to calibrate the CR-39 Solid State Nuclear Track Detector (SSNTD), a closed -circulation type SSNTD-Calibration-System containing a radon-cup with the Millipore filter has been set-up, and the tracks produced on the SSNTD were measured for the known amount of radon concentration. Calibration factor for the time integrated radon concentration as a function of the track density on CR-39 was estimated to be $0.24{pm}0.09(pCi/l);day/(Tr/cm^2)$.
Editorial Office
#319, Hanyang Institute of Technology Bldg., 222 Wangsimni-ro, Seongdong-gu,Seoul, Republic of Korea
Tel: +82-2-2297-9775   Fax: +82-2-2297-9776
Email: managing.editor@jrpr.org
About |  Browse Articles |  Current Issue |  For Authors and Reviewers
Copyright © by Korean Association for Radiation Protection. Developed in M2PI