EGS4 simulation을 이용한 2차원 방사선준위 분포측정 시스템의 Response Matrix 계산
김성환;한상효;강희동;김재철;박인규;최영수;이용범;이종민;
The Calculation of Response Matrix of 2-Dimensional Radiation Monitoring System Using EGS4 Simulation
Kim, S.H.;Han, S.H.;Kang, H.D.;Kim, J.C.;Park, I.K.;Choi, Y.S.;Lee, Y.B.;Lee, J.M.;
ABSTRACT
In this study an EGS4 simulation code was used to calculate real energy spectrum from measured ${gamma}$-ray energy spectrum obtained using 2-dimensional radiation monitoring system. As a result, the $39{times}39$ response matrix was calculated the energy range of 0.1 to 2 MeV which energy interval of 50 keV The real energy spectrum for Co-60 radioisotope was calculated using inverse of response matrix. It was confirmed that the calculated response matrix was useful to the analysis of the measured energy spectrum for the radiation monitoring system.