| Home | E-Submission | Sitemap | Contact Us |  
top_img
J Radiat Prot > Volume 6(1); 1981 > Article
Journal of Radiation Protection 1981;6(1):34-0.
고 에너지 방사선 치료실의 차폐계산과 누출선량의 측정
추성실;박찬윤;
Measurement of Leakage and Design for the Protective Barrier of the High Energy Radiation Therapy Room
Chu, Sung-Sil;Park, Chang-Yun;
ABSTRACT
The logical development of an optimum structural shielding design and the computation of protective barriers for high energy radiation therapy room, Toshiba 13 MeV. are presented. We obtained following results by comparison in between the precalculating values and actual survey after complete installation of radiogenerating units. 1. The calculating formula for the protective barrier written in NCRP report #34(1970) was the most ideal and economic calculating methods for the construction of barrier and to determine thickness for the meeting requirements of the number of patients of 80-100 in daily treatment. 2. The precalculating values of protective barrier are 5 times more protective than that of actual measurement. It is depending on radiation workload and utilization the datas most sequrely. 3. The dose rate during exposure are 2-10 mR/hr at out of the door and the controll room. 4. The foul smelling and ozone gas production from long exposure of cancer patients cannot be eliminated when the room is ill ventilated.
TOOLS
PDF Links  PDF Links
Full text via DOI  Full text via DOI
Download Citation  Download Citation
Share:      
METRICS
3,957
View
5
Download
Development of the Algorithm for On-line Dosimetry System for High Energy Radiation Treatment  1997 ;22(3)
Editorial Office
#319, Hanyang Institute of Technology Bldg., 222 Wangsimni-ro, Seongdong-gu,Seoul, Republic of Korea
Tel: +82-2-2297-9775   Fax: +82-2-2297-9776
Email: managing.editor@jrpr.org
About |  Browse Articles |  Current Issue |  For Authors and Reviewers
Copyright © by Korean Association for Radiation Protection. Developed in M2PI