The Determination of Radon Progeny Concentration in Controlled Radon Environment
Seo, Kyung-Won;Lee, Byung-Kee;
ABSTRACT
A standard radon chamber and a radon generator adjusted by ventilation system which had used in this research were assumed to calculate theoretically the concentration of radon progeny using Jacobi model theory. On the one hand, the filter sampled from the radon standard chamber and the radon generator was measured and analysed by the alpha spectrometry method. It is clear that measured result shows a good agreement with theoretical result. Therefore, it is observed that this research can made a great contribution to more accurate internal dose assessment by alpha emission of radon progeny in indoor radon environment, and fast individual measurement and determination of concentration for radon progeny.