J Radiat Prot > Volume 22(4); 1997 > Article
Journal of Radiation Protection 1997;22(4):243-0.
라돈농도 측정을 위한 고체비적검출기의 상대교정법 개발 및 응용
박영웅;양현수;
Development of Relative Calibration Method for Measurement of Radon and Application
Park, Young-Woong;Yang, Hyun-Soo;
ABSTRACT
A relative-calibration-method of solid-state-track-detector for measurement of radon in air has been developed, and the concentration of radon in each room of a 15th-floor-apartment was measured by using the relative calibrated SSTD. There is a tendency to decrease the concentration of radon when the floor is higher, but the main factor to reduce the concentration of radon in room appeared to be ventilation rate. Average concentration of radon of the 15th-floor-apartment was $1.50{pm}0.51pCi/l$, and the highest and the lowest concentration of radon were $2.68{pm}0.32pCi/l$, $0.69{pm}0.16pCi/l$ respectively.